012-1005

Capacity with 0.5 gpm flow* and 150C delta T** = 468 watts (1600 btu/hr)

Overall Size
*** L x W x H
 Refrigerant Connection
IN x OUT
Water Connection
IN x OUT
10 3/4" x 7 3/4" x 3" 1/4" ID x 1/4" ID 3/8" OD x 3/8" OD

*  Water flow through the exchanger.
** The temperature difference between the refrigerant and the water flowing through the tubes (average).
*** The length given includes the straight connection extensions.